Miscellaneous Drainage Joints

Drainage Details

Taylor & Francis, 1988

Book chapter

0

... Clay Pipe Socket to Cast Iron Socket to Cast Iron Spigot Clay Pipe Spigot 9S467 No. 25 Connector * with special wide socket ............. Clay Pipe Socket to Cast Iron Socketto Pitch Fibnt Spigot Pitch Fibre Spigot * Clay Pipe...

Drain Testing

Drainage Details

Taylor & Francis, 1988

Book chapter

0

... IMPORTANCE OF TESTING TESTING PROCEDURE 'We desire to emphasise that the application of a suitable test to a new A For equipment used drainage system is a matter of great see detail sheet No. 38 importance to the workmen...

Selection of Gullies

Drainage Details

Taylor & Francis, 1988

Book chapter

0

... CLAY Yard gully to 8S65 Angle or Phillips Gully Reversible Gully R o u n d to p fo r u s e w ith r a is in g p ie c e Hopper can be turned in P la in e n d e d any direction independent P 't r a p of trap ,6 4 m m Available...

Cast Iron Pipes and Joints

Drainage Details

Taylor & Francis, 1988

Book chapter

0

... PIPES Centrifugally cast ('spun') iron 3. Under buildings. Materials of less pipes for water, gas and sewage. strength than cast iron can be BS1211 :1981 considered for this situation without the Socket requirement of being surrounded...

Drain Testing Equipment

Drainage Details

Taylor & Francis, 1988

Book chapter

0

... BUILDING REGULATIONS EQUIPMENT FOR PLUGGING Approved Document H1 - watertightness. Item 2.27 lays down minimum standards Expanding drain plugs Plugging top of vent pipe for gravity drains and private sewers up to Sizes range from 50 mm...

upvc Underground Drains

Drainage Details

Taylor & Francis, 1988

Book chapter

0

... PIPES AND FITTINGS At present time, three groups of British 8tandard specifications cover upvc pipes Pipes can be supplied - Universal Inspection Chamber - recommended for use as drain or sewer 1. Both ends plain (use coupling...

Intercepting Traps

Drainage Details

Taylor & Francis, 1988

Book chapter

0

... CLAY BS Channel Interceptor Detail of Intercepting Chamber Fresh Air Inlet Available in 100 mm to 450 mm - Fresh air inlet nominal bore sizes (see section below) To receive stopper Type B Vertical Inspection 600 mm -100m pipe Levelling...

Selection of Junctions

Drainage Details

Taylor & Francis, 1988

Book chapter

0

... CLAY Square Curved Square Oblique Also available as half section 8865 Also available as 8865 8865 Also available as half section channel junctions half section channel junctions channel junctions 90" ( 90° Branch Angle Junction...

Sewage Lifting by Pumping (1)

Drainage Details

Taylor & Francis, 1988

Book chapter

0

... INTRODUCTION TYPICAL LAYOUT DETAIL Pumping stations are weak points in any drainage system and every effort should be IrYPiCal arrangement of a made when planning a drainage system to I "Wet Well" two pump station avoid the necessity...

Discharge in Pipes and Channels

Drainage Details

Taylor & Francis, 1988

Book chapter

0

... FORMULAE FOR DISCHARGE TRANSPOSITION Circular pipes or channels flows of any Circular pipes only flowing full or half depth full Full ttD2 All are for full or half full bore discharges in 4 Full Half Full circular pipes. Divide...